
Free HQT-4160 pdf Files With Updated and Accurate Dumps Training
Top-Class HQT-4160 Question Answers Study Guide
The Hitachi Vantara Qualified Professional - VSP 5000 Series Installation certification exam comprises a combination of theoretical and practical knowledge assessments. HQT-4160 exam is computer-based and proctored. The candidates have 90 minutes to complete the exam and answer 60 questions. HQT-4160 exam is available in English and Japanese languages. Hitachi Vantara Qualified Professional - VSP 5000 Series Installation certification remains valid for two years after the date of issuance, and candidates must renew their certification to retain their Hitachi Vantara Qualified Professional status. Candidates can take HQT-4160 exam at any authorized Hitachi Vantara testing center. In summary, the Hitachi HQT-4160 certification exam is globally recognized and designed to validate the candidates' ability to install and configure the Hitachi Vantara VSP 5000 series products.
The Hitachi Vantara Qualified Professional - VSP 5000 Series Installation certification exam is conducted online and consists of multiple-choice questions. HQT-4160 exam is time-limited, and candidates have a limited amount of time to complete it. HQT-4160 exam is designed to test the knowledge and skills of candidates in a variety of areas, including installation and configuration, storage management, and advanced features. Successful candidates will receive a certificate that validates their expertise in the Hitachi VSP 5000 Series.
NEW QUESTION # 10
VSP 5000 systems use which of the following technologies for connectivity? (Choose two)
- A. NVMe-oF
- B. SATA
- C. Fibre Channel
- D. IDE
Answer: A,C
Explanation:
The Hitachi VSP 5000 storage system supports high-performance connectivity technologies to connect hosts and storage networks:
Fibre Channel (A)
A widely used SAN protocol for high-speed, low-latency storage connectivity.
Provides reliable and scalable connections between servers and storage arrays.
NVMe over Fabrics (NVMe-oF) (C)
Enables ultra-low latency access to NVMe storage across a network fabric.
Increasingly used for high-performance workloads requiring fast data access.
NEW QUESTION # 11
How many Accelerator Compression Modules are installed in a VSP 5600?
- A. two per system
- B. two per CBX
- C. three per controller
- D. two per controller
Answer: D
Explanation:
Each controller in the VSP 5600 system is equipped with two Compression Accelerator Modules.
NEW QUESTION # 12
To perform configuration changes on VSP 5000 systems without affecting data availability, the changes must be:
- A. Performed manually by a technician
- B. Approved by the system administrator
- C. Scheduled during system downtime
- D. Executed online with appropriate planning
Answer: D
Explanation:
The Hitachi VSP 5000 is designed for high availability and supports online configuration changes.
This allows administrators to:
Modify RAID groups, volumes, or storage pools
Update network or host assignments
Perform maintenance tasks
...without taking the system offline, as long as the changes are carefully planned to avoid disrupting active data paths.
NEW QUESTION # 13
How many Channel Boards (CHBs) can be installed in a VSP 5600 with two CBX?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
Explanation:
In a VSP 5600 system configured with two Controller Boxes (CBXs), you can install up to 16 Channel Boards (CHBs) in total. Each CBX can accommodate up to 8 CHBs, resulting in a combined maximum of 16 CHBs for the system. This configuration allows for scalable host connectivity options, supporting various protocols such as Fibre Channel, iSCSI, and FICON.
NEW QUESTION # 14
You need to add another SBX with 4 drive boxes (DBS2) and 16 drives to a VSP 5100. What is the correct procedure?
- A. Insert the drives in the DBs. Mount the DBs in the rack and attach the cables. Install the drives with the Maintenance Utility.
- B. Insert the drives in the DBs. Mount the DBs in the rack and install them with the Maintenance Utility.
- C. Mount the empty DBs in the rack. Insert the drives in the DBs and install them with the Maintenance Utility.
- D. Mount the empty DBs in the rack and attach the cables. Install the DBs with the Maintenance Utility. Insert the drives in the DBs and install them with the Maintenance Utility.
Answer: C
Explanation:
The correct procedure is to first mount the empty drive boxes (DBs) in the rack, then insert the drives into the DBs, and finally use the Maintenance Utility to install and configure the new hardware. This ensures proper detection and initialization by the system.
NEW QUESTION # 15
Which tool do you use to configure SNMP on a VSP 5000 storage system?
- A. Webconsole
- B. Maintenance Utility
- C. Maintenance Utility Sub Panel
- D. SVP application
Answer: D
Explanation:
The SVP (Service Processor) application is used to configure SNMP settings on a VSP 5000 storage system. This tool provides access to system management features, including SNMP configuration.
NEW QUESTION # 16
Which two part replacements in a VSP 5000 system require blocking the controller? (Choose two.)
- A. Hitachi Interconnect Edge (HIE)
- B. Cache DIMM
- C. Controller PCB
- D. Cache Flash Module (CFM)
Answer: B,C
Explanation:
Controller PCB
Replacing the Controller PCB requires blocking the controller to ensure system integrity and prevent data loss during the hardware change.
Cache DIMM
Cache DIMMs are part of the controller's critical memory subsystem, so the controller must be blocked before replacing any cache DIMMs to avoid corruption and ensure a safe replacement process.
NEW QUESTION # 17
A customer wants to upgrade a VSP 5500 to a VSP 5600. Which two actions are required for this upgrade? (Choose two.)
- A. Replace all the Power Supplies with more powerful ones.
- B. Replace the CPUs on all the controller boards.
- C. Replace all the controller boards.
- D. Replace all the memory DIMMs.
Answer: A,C
Explanation:
Replace all the controller boards.
Upgrading from VSP 5500 to VSP 5600 requires installing new controller boards, as the 5600 uses a different and more advanced controller architecture.
Replace all the Power Supplies with more powerful ones.
The upgrade also requires replacing the power supplies with models that are compatible with and can support the power requirements of the VSP 5600 controllers.
NEW QUESTION # 18
You need to upgrade the cache of a VSP 5500 online. How do you accomplish this task?
- A. Use Storage Navigator to put the CHB Adapters offline one controller at a time, and add the extra cache to the inactive controller.
- B. Use the VSP GUI and click on Change Configuration and follow the instructions on the screen to add the extra cache.
- C. Use the Maintenance Utility to block the controllers one at the time, and add the extra cache to the blocked controller.
- D. Use the Web Console to block the controllers one at the time, and add the extra cache to the blocked controller.
Answer: C
Explanation:
To upgrade the cache online, you must use the Maintenance Utility to sequentially block each controller, add the extra cache modules to the blocked controller, and then unblock it, ensuring system availability throughout the process.
NEW QUESTION # 19
Which three ISO files are part of the Microcode Kit for the VSP 5000 series? (Choose three.)
- A. Open Source Software (OSS)
- B. Microcode (R9)
- C. Maintenance PC (MPC)
- D. Custom Tools (CT)
- E. Documents and Programs (DP)
Answer: A,B,E
Explanation:
Documents and Programs (DP)
This ISO contains the necessary documentation and utility programs required for microcode installation and maintenance.
Microcode (R9)
This ISO provides the actual microcode (firmware) that is installed onto the VSP 5000 series hardware.
Open Source Software (OSS)
This ISO includes open source software components required by the system or referenced during installation.
NEW QUESTION # 20
During the parts-replacement process on a VSP 5000 storage system, what is the recommended action before removing any component?
- A. Notifying all connected users about the impending downtime
- B. Isolating the power supply to the specific component
- C. Documenting the serial number of the component
- D. Ensuring the system is in maintenance mode
Answer: D
Explanation:
Before replacing any component in a Hitachi VSP 5000 storage system, it is critical to put the system or the affected controller/module into maintenance mode.
This ensures:
No active I/O is directed to the component being replaced.
Data integrity is preserved during the removal and replacement process.
The system prevents accidental disruptions to other parts of the storage array.
Automatic failover or rebuild processes do not interfere with the replacement.
NEW QUESTION # 21
You need to install an iSCSI channel board feature on a VSP 5500 system. Which two steps are required? (Choose two.)
- A. Physically install the pair of channel boards in the appropriate slots.
- B. Use the Maintenance Utility (Sub Panel) of the VSP GUI to assign ports to the added boards.
- C. Use the Maintenance Utility to add the boards to the system configuration.
- D. Physically install the pair of channel boards in any available slot.
Answer: A,C
Explanation:
Physically install the pair of channel boards in the appropriate slots.
Channel boards must be installed in specific, designated slots to ensure proper system recognition and redundancy.
Use the Maintenance Utility to add the boards to the system configuration.
After installation, the Maintenance Utility is used to logically add and configure the new channel boards within the system.
NEW QUESTION # 22
Which two statements are true about the spare drive in a VSP 5000 system? (Choose two.)
- A. The customer can decide which slot is to be used for the spare drive.
- B. If one of the slot 11 of the SBX is used as spare, the 3 remaining slots 11 could only be used as spare.
- C. Only slot 11 and slot 23 of DBS2 can be used as spare.
- D. The VSP 5000 system will allocate a spare slot automatically if "Spare slot allocation" is set to
"Variable" at installation time.
Answer: A,D
Explanation:
The customer can decide which slot is to be used for the spare drive.
With "Fixed" spare slot allocation, the customer has the flexibility to select which drive slot will serve as the spare during system configuration.
The VSP 5000 system will allocate a spare slot automatically if "Spare slot allocation" is set to
"Variable" at installation time.
If the "Variable" option is chosen for spare slot allocation, the system automatically selects and assigns spare drive locations.
NEW QUESTION # 23
How do you validate the network settings configuration on a newly installed VSP 5000 storage system?
- A. Using an external network configuration audit tool
- B. Through the management console's network test function
- C. By disconnecting and reconnecting the network cables
- D. By performing a system reboot
Answer: B
Explanation:
The Hitachi VSP 5000 storage system provides a built-in management interface that allows administrators to verify configuration settings after installation.
Using the management console network test tools, administrators can:
Validate IP configuration
Check network connectivity
Verify gateway and DNS settings
Test communication with management hosts or monitoring systems
These built-in diagnostic functions help ensure that the network configuration is correct and operational before the system goes into production.
NEW QUESTION # 24
Configuration of the _______ is crucial for integrating VSP 5000 systems with existing IT environments.
- A. SVP Agent
- B. security protocols
- C. network settings
- D. user permissions
Answer: C
Explanation:
Proper network configuration is essential when integrating the Hitachi VSP 5000 storage system into an existing IT infrastructure.
Network settings ensure that the storage system can communicate with hosts, switches, and management platforms within the organization's environment.
Key network configuration tasks include:
Assigning IP addresses to management interfaces
Configuring subnets and gateways
Setting up DNS and routing
Ensuring connectivity to SAN or Ethernet networks
Integrating with monitoring and management systems
Without proper network configuration, the storage system may not be accessible or manageable within the enterprise environment.
NEW QUESTION # 25
In a VSP 5100 a drive in a RAID5 Parity Group has failed and has been blocked by the microcode. As a result, which process gets automatically started?
- A. Dynamic Sparing
- B. Correction Copy
- C. Copy Back
- D. Sparing Copy
Answer: B
Explanation:
When a drive in a RAID5 Parity Group fails and is blocked by the microcode in a VSP 5100, the Correction Copy process is automatically started to rebuild the data onto a spare drive.
NEW QUESTION # 26
Which statement is correct regarding the Interconnect Switches (ISWs) on VSP 5000 systems?
- A. ISWs are switches that route data between nodes and they are located on each controller of the node.
- B. ISWs are switches that route data between nodes using Hitachi Interconnect Edge and X-Path cables, and they are located on the Hitachi Service and Network Boxes (HSNBXs).
- C. ISWs are standalone, optional switches than can be used for both network and data path.
- D. ISWs are switches that provide redundancy for data path and they are only used when the number of CBX pairs is higher than two.
Answer: C
Explanation:
The Interconnect Switches on a VSP 5000 are delivered as standalone 1 U switch chassis that house both the PCIe "interconnect" modules (for routing data between controller nodes) and an Ethernet switch (for management/network traffic), so they serve both network and data-path roles.
NEW QUESTION # 27
A disk drive is in failed state in a VSP 5600 system and you want to replace it. Which two actions should you perform as part of the replacement procedure? (Choose two.)
- A. Initiate the Correction Copy process.
- B. Replace the drive.
- C. Activate Dynamic Sparing.
- D. Block the drive with the Maintenance Utility.
Answer: B,D
Explanation:
Replace the drive.
Physically replacing the failed drive is a required step in the drive replacement procedure.
Block the drive with the Maintenance Utility.
Before removal, the failed drive should be logically blocked using the Maintenance Utility to safely isolate it from the system and prevent I/O errors during replacement.
NEW QUESTION # 28
Which three Channel Board (CHB) protocols are supported on a VSP 5000 system? (Choose three.)
- A. FC
- B. iSCSI
- C. SCSI
- D. FICON
- E. Wide SCSI
Answer: A,B,D
Explanation:
iSCSI
The VSP 5000 supports iSCSI Channel Boards, enabling block storage over IP networks.
FICON
FICON Channel Boards are supported for mainframe connectivity.
FC
Fibre Channel (FC) Channel Boards are supported for high-performance SAN connectivity.
NEW QUESTION # 29
You are installing a VSP 5500h with 3 pairs of CBXs. What is the total number of X-PATH cables that will be attached to the ISW ports?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
Explanation:
A VSP 5500h system with 3 pairs of Controller Boxes (CBXs) requires a total of 48 X-PATH cables attached to the Interconnect Switch (ISW) ports. Each CBX pair contributes 16 X-PATH cables (8 per CBX), and with 3 pairs, the total is 3 × 16 = 48.
NEW QUESTION # 30
What is a critical step in the pre-installation checklist for ensuring the physical security of the VSP
5000 system?
- A. Configuring firewall settings
- B. Securing the racks to the floor
- C. Setting BIOS passwords
- D. Installing surveillance cameras in the data center
Answer: B
Explanation:
The Hitachi VSP 5000 is a large enterprise storage system typically installed in data center racks.
A key pre-installation physical security and safety requirement is ensuring that racks are properly anchored or secured to the floor.
This step is critical because:
The storage system is heavy and tall, creating a tip-over risk.
Anchored racks improve stability during maintenance (when components are extended).
It protects equipment from accidental movement or vibration.
Many data center safety standards require rack anchoring before installation.
NEW QUESTION # 31
When a hot spare drive is activated in a VSP 5000 system, it's important to:
- A. Immediately order a replacement for the hot spare
- B. Power down the system to avoid data loss
- C. Perform a full backup of the system
- D. Reconfigure the RAID settings
Answer: A
Explanation:
In the Hitachi VSP 5000 storage system, a hot spare is a drive reserved to automatically replace a failing drive in a RAID group. When it is activated:
The hot spare takes over the failed drive, and RAID rebuild begins.
At this point, the system no longer has a spare available for future failures.
Therefore, it is critical to order and install a new hot spare as soon as possible to maintain full redundancy and data protection.
NEW QUESTION # 32
What are two ways to identify that a problem occurred on a VSP 5000 system? (Choose two.)
- A. An Alert Information Message (AIM) was generated and communicated by SNMP to notify the customer.
- B. The Master Alarm LED at the top right of the front door is lit.
- C. A SIM was generated and could be displayed using the SVP GUI.
- D. The Remote Ops SVP Agent called home and a support case was generated.
Answer: B,C
Explanation:
The Master Alarm LED at the top right of the front door is lit.
A lit Master Alarm LED is a direct hardware indicator that a problem has occurred on the system.
A SIM was generated and could be displayed using the SVP GUI.
A Service Information Message (SIM) indicates an event or error and can be viewed via the SVP GUI, helping identify and diagnose system issues.
NEW QUESTION # 33
......
Hitachi VSP 5000 series is a high-performance storage system that provides scalability, reliability, and flexibility to meet the needs of modern data centers. It is a powerful solution that can handle the most demanding workloads, including artificial intelligence, machine learning, and big data analytics. The VSP 5000 series is designed to deliver high availability and performance while reducing operational costs, making it an ideal choice for enterprise-level organizations.
Real Updated HQT-4160 Questions & Answers Pass Your Exam Easily: https://www.dumpsquestion.com/HQT-4160-exam-dumps-collection.html
Easily To Pass New HQT-4160 Verified & Correct Answers: https://drive.google.com/open?id=1BIDiES2gn6bPtdJnsoqsBOC8bScaRWjl