NEW QUESTION # 209
What should you do with equipment manuals and software documentation?
Select all that apply.
Response:
- A. Leave a copy with the AV rack
- B. Leave a copy in the storage closet
- C. Arrange them by function
- D. Arrange them in alphabetical order
Answer: A,C,D
NEW QUESTION # 210
What kind of material might be used in some rear projection screen applications?
- A. opaque
- B. high-gloss
- C. Reflective
- D. diffused
Answer: D
NEW QUESTION # 211
When mounting a 75 lb (34 kg) projector with a 15 lb (7 kg) mount, the substructure should be able to support a minimum weight of:
[Conducting Site Rough-In/First-Fix/Mount Substructure]
Response:
- A. 90 lbs (41 kg)
- B. 180 lbs (82 kg)
- C. 270 lbs (122 kg)
- D. 450 lbs (204 kg)
Answer: D
NEW QUESTION # 212
When working with electrical systems, what should you do if two codes have conflicting requirements?
- A. Consult the NEC handbook and do only what it says
- B. Follow the guidelines from the most restrictive code
- C. Follow the guidelines from the most lenient code
- D. Ignore both of the codes and do the installation in a way that makes sense to you
Answer: B
NEW QUESTION # 213
In an electrical system, a ground fault is ___.
Response:
- A. an electrical connection between any grounded conductor and any non-current-carrying metal object
- B. a continuous isolation between receptacles and electrical circuits
- C. an electrically conductive area that has two or more ground reference connections
- D. an interruption of a cable shield connection
Answer: A
NEW QUESTION # 214
What are key considerations when determining projector placement?
Select all that apply.
Response:
- A. Throw distance
- B. Type of lens
- C. Offset value
- D. Standard deviation
Answer: A,B,C
NEW QUESTION # 215
On which type of cable should you avoid using cable lubricants?
- A. Shielded cable
- B. Fiber optic cable
- C. Coaxial cable
- D. CAT5e cable
Answer: B
NEW QUESTION # 216
The difference between the loudest and quietest levels of an audio signal is the ___.
Response:
- A. dynamic range
- B. frequency range
- C. stereo level
- D. volume level
Answer: A
NEW QUESTION # 217
The red wire in a loudspeaker cable carries a ___ signal.
Response:
- A. negative
- B. positive
- C. ground
- D. neutral
Answer: B
NEW QUESTION # 218
Native resolution is the ___ resolution for the display.
- A. average pixel distribution
- B. modified
- C. downscaled
- D. optimized
Answer: D
NEW QUESTION # 219
If you go up one octave from 250 Hz, you arrive at _____.
- A. 500 Hz
- B. 251 Hz
- C. 1250 Hz
- D. 125 Hz
Answer: A
NEW QUESTION # 220
The ANSI/AVIXA 2M-2010 Standard Guide for Audiovisual Systems Design Coordination Processes lays out a procedure for determining the:
- A. room types that are suitable for a given set of client needs
- B. project communication that needs to take place on a given project
- C. functions and features that are required to support a given set of tasks
- D. verification tests that should be performed during a given project
Answer: B
NEW QUESTION # 221
When mounting equipment to a concrete substructure, which fastener is the most likely to be used?
- A. Self tapping screw
- B. Drop in Anchor
- C. Molly Bolt/hollow wall anchor
- D. Toggle Bolt/Spring Toggle
Answer: B
NEW QUESTION # 222
What Viewing Category applies to a space used for word processing and spreadsheets?
- A. Both ADM and BDM
- B. BDM
- C. ADM
Answer: B
NEW QUESTION # 223
Which of the following are elements of a control system? (Choose all that apply.)
- A. Firmware
- B. Spyware
- C. Software
- D. Hardware
Answer: A,C,D
NEW QUESTION # 224
The key elements of a project should be driven by:
- A. The overall budget
- B. The client's need
- C. The cost of materials
- D. The deadline for completion
Answer: B
NEW QUESTION # 225
When mounting equipment to a concrete substructure, which fastener is the most likely to be used?
Response:
- A. Self tapping screw
- B. Drop in Anchor
- C. Molly Bolt/hollow wall anchor
- D. Toggle Bolt/Spring Toggle
Answer: B
NEW QUESTION # 226
When demonstrating the operation of a digital visual system with multiple connections for laptops, it is recommended to:
Response:
- A. Connect the laptops to confirm that they will properly display the resolution set by the EDID table
- B. Use a video test pattern generator to test all laptop connections
- C. Only explain the different resolutions that the system is capable of displaying
- D. Utilize a professional test generator to confirm that the system will output the proper resolution set by the EDID table.
Answer: A
NEW QUESTION # 227
Why is it a good idea for the AV installer to provide end-user training on a new system?
- A. Good opportunity to identify punch or defects list items
- B. It reduces the number of service calls and damaged equipment caused by user error
- C. To identify future sales opportunities
- D. Most state codes require service after the sale
Answer: B
NEW QUESTION # 228
......