HPE2-T37 Exam Study Guide Free Practice Test LAST UPDATED DATE Jun 29, 2022 [Q37-Q60]

Share

HPE2-T37 Exam Study Guide Free Practice Test LAST UPDATED DATE Jun 29, 2022

The New HPE2-T37 2022 Updated Verified Study Guides & Best Courses


HP HPE2-T37 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Architect and design a data center management solution using the HPE OneView
Topic 2
  • Manage and report on Hybrid IT infrastructure using HPE OneView
Topic 3
  • Describe industry standard data center infrastructure management technologies

 

NEW QUESTION 37
Click the option that must be configured for an HPE OneView when an HPE storage system is connected directly to an HPE Synergy frame.

Answer:

Explanation:

 

NEW QUESTION 38
You want to update the firmware for only two HPE Synergy Virtual Connect SE 32Gb FC Modules of a large environment. From which level must this procedure be initiated?

  • A. Logical Enclosure
  • B. Server Profile
  • C. Logical Interconnect Group
  • D. Logical Interconnect

Answer: A

 

NEW QUESTION 39
Which statement about the presented storage pools is true?

  • A. All storage pools in managed state have a valid HPE OneView license applied
  • B. HPE OneView can be used to configure replication only between managed storage pools
  • C. All storage pools from the system named ThreePAR-1 can be used for volume provisioning
  • D. Storage pools in discovered state can be removed from HPE OneView.

Answer: C

 

NEW QUESTION 40
Your workload profile in the BIOS. All of the servers are managed using HPE OneView.
How can this task be completed?

  • A. Set a specific workload profile within server profile template and update all profiles.
  • B. Set a specific workload profile for all managed servers as an HPE OneView global setting.
  • C. Set a specific workload profile using IL0 interface for each individual server.
  • D. Set a specific workload profile within Logical Interconnect Group and update all servers.

Answer: A

 

NEW QUESTION 41
Your customer asks you if it is possible to perform HPE Synergy initial setup remotely. How should you respond?

  • A. Remote HPE Synergy Installation can be done only if an additional set of the services was purchased together with hardware platform.
  • B. Remote HPE Synergy setup is possible if HPE Composer 2 is used and a DHCP server Is available in the management network.
  • C. HPE Synergy cannot be deployed remotely, as Initial setup must be performed using a local console connection.
  • D. HPE Synergy can be configured remotely through a secure connection to the FLM if this option was enabled In the factory.

Answer: D

 

NEW QUESTION 42
You ate implementing an HPE Synergy solution with multiple frames in one management ring. Image Streamer is not a part of this solution. How can an IPv4 address pool defined by the administrator be used In HPE OneView?

  • A. to provide static IP addresses for storage systems managed in HPE OneView
  • B. to provide static IP addresses to IL0 and interconnect modules if applicable
  • C. to provide static IP addresses for an operating system running on a Compute Module
  • D. to provide static IP addresses for Logical Interconnects and Logical Enclosures

Answer: B

 

NEW QUESTION 43
Which statement about a server profile for an Apollo system is true?

  • A. Virtual WWNs and MAC addresses can be defined
  • B. Enclosure Group Is automatically selected
  • C. Fibre Channel connections can be defined
  • D. UEFI optimized is the only available boot mode

Answer: A

 

NEW QUESTION 44
Which statement about a server profile for an Apollo system is true?

  • A. Fibre Channel connections can be defined
  • B. Virtual WWNs and MAC addresses can be defined
  • C. Enclosure Group Is automatically selected
  • D. UEFI optimized is the only available boot mode

Answer: A

 

NEW QUESTION 45
Which parameters can be defined in a server profile template for HPE Synergy Compute Modules? (Select two.)

  • A. network and storage connectivity.
  • B. IL0 IPv4 or IPv6 address.
  • C. local storage and BIOS settings.
  • D. partition layout for servers running Linux.
  • E. NIC teaming setup at OS level.

Answer: A,C

 

NEW QUESTION 46
Your customer added HPE Primera to HPE OneVlew and enabled volume provisioning on all storage pools. For security reasons, the customer wants to disable volume provisioning using HPE OneView on a specific storage pool.
How can this task be completed?

  • A. The storage pool state should be changed to discovered using HPE OneView.
  • B. The storage pool should be marked as read-only using HPE OneView.
  • C. The storage pool should be disabled using the array management tool.
  • D. The storage pool should be removed from HPE OneView using a PowerShell script.

Answer: C

 

NEW QUESTION 47
Refer to the exhibit.

Your customer wants to define a Logical Interconnect Group (UG) and set the redundancy of the master modules to highly available, but this option is not available. What is a possible reason?

  • A. Firmware on the master modules is too low to support highly available setup.
  • B. Some master modules only support a redundant setup.
  • C. There are not sufficient frames for highly available setup.
  • D. A dedicated license must be added to HPE OneView to enable this feature.

Answer: B

 

NEW QUESTION 48
You want to add the latest IL0 firmware to an HPE OneView firmware repository. How can you complete this task?

  • A. An external repository must be created, because standalone components are supported only In an external repository.
  • B. A custom SPP iso Image must be created with the new IL0 firmware version and uploaded to the repository.
  • C. A PowerShell script must be used to upload IL0 firmware to the Internal or external firmware repository.
  • D. ILO firmware can be marked as a hotnx and uploaded directly to the Internal or external firmware repository.

Answer: A

 

NEW QUESTION 49
You want to put two FlexNlCs into a single Link Aggregation Group within a server profile. What Is a prerequisite for this setup?

  • A. Both FlexNlCs must be connected to the same network.
  • B. The Compute Module profile must have exactly two connections defined.
  • C. An upgrade license must be purchased and deployed.
  • D. The sFlow option must be enabled and configured.

Answer: D

 

NEW QUESTION 50
Click option that will allow you to select a FlexNIC function for the specified connection.

Answer:

Explanation:

 

NEW QUESTION 51
Which statement about access to HPE Onboard Administrator is true when an HPE BladeSystem enclosure is added to HPE OneView?

  • A. It is blocked when HPE BladeSystem enclosure is monitored using HPE OneView.
  • B. It is enabled when an HPE BladeSystem is either managed or monitored using HPE OneView.
  • C. It is blocked when an HPE BladeSystem enclosure is managed using HPE OneView.
  • D. It is enabled only when an HPE BladeSystem enclosure is monitored using HPE OneView.

Answer: D

 

NEW QUESTION 52
Which statement about logical JBODs configured using KPE OneView and D3940 Storage Modules is true?

  • A. Different types of the drives can be used within a logical JBOD as long as they have the same capacity
  • B. Logical JBOD functionality must be enabled on the Enclosure Group level by a storage administrator
  • C. A logical JBOD lifecycle can be associated with a server profile lifecycle and drives can be securely erased.
  • D. A logical JBOD cannot be created during server profile creation and must be prepared in advance

Answer: D

 

NEW QUESTION 53
Your customer wants to manage their HPE Superdome Flex using HPE OneView.
Which component must be added to HPE OneView to accomplish this task?

  • A. all nPARs created within the complex
  • B. only the base chassis from the complex
  • C. Rack Management Controller (RMC)
  • D. Baseboard Management Controller (BMC)

Answer: D

 

NEW QUESTION 54
Which statement about M-LAG setup is true?

  • A. M-LAG for HPE Synergy can be either single-homed or multi-homed, while for HPE BladeSystem only single-homed.
  • B. M-LAG has to be defined manually for HPE BladeSystem, but it is automatically configured for HPE Synergy.
  • C. When combined with IRF, M-LAG will allow you to aggregate ports coming from clustered HPE Synergy Virtual Connect modules.
  • D. sFLOW cannot be enabled if M-LAG is configured between HPE Synergy Virtual Connect modules in the same frame.

Answer: C

 

NEW QUESTION 55
Which statement about HPE OneView Global Dashboard is true?

  • A. It is a plugin to HPE Oneview that will allow integration of HPE oneView with VMware management and monitoring components
  • B. It is a virtual appliance that can aggregate health and inventory information from multiple HPE OneView appliances or HPE Composers
  • C. It is an application that can be installed on Windows or Linux system that will provide automated discovery of HPE OneView instances
  • D. It is a plugin to vCenter Server that will allow management of the components added to HPE Oneview from vCenter server interface

Answer: B

 

NEW QUESTION 56
Refer to the exhibit.

After adding SAN Manager to HPE OneView. you noticed that all SANs are in the discovered state. How will this affect HPE OneView storage management capabilities?

  • A. Snapshot functionality will be limited only to the volumes not using these SANs.
  • B. Volume provisioning will only work for arrays that ate accessible through these SANs.
  • C. Volume presentation through server profile will work with the discovered state.
  • D. Auto-zoning functionality will not work until SANs are associated with networks.

Answer: C

 

NEW QUESTION 57
For HPE Primera, match each task with the management tool that can be used to perform it.

Answer:

Explanation:

 

NEW QUESTION 58
As a part of troubleshooting, you have to reinstall the same version of the firmware on an HPE Synergy Compute Module. Click the area within the Firmware section of the server profile that will allow you to install the same firmware version.

Answer:

Explanation:

 

NEW QUESTION 59
You have created volumes using array management tools and imported the volumes to HPE OneView.
Which statement about these volumes is true?

  • A. Volumes imported to HPE OneView is managed just like a volume created using HPE OneView
  • B. A snapshot for imported volumes can be created only by using array management tools
  • C. Volumes imported to HPE OneView cannot be removed using the HPE OneView interface
  • D. Imported volumes are treated as private volumes and can be only used as boot volumes

Answer: D

 

NEW QUESTION 60
......

Get Prepared for Your HPE2-T37 Exam With Actual 81 Questions: https://www.dumpsquestion.com/HPE2-T37-exam-dumps-collection.html

Authentic HPE2-T37 Exam Dumps PDF - 2022 Updated: https://drive.google.com/open?id=1QVDuhOafa8NAwf8N3tZbLgqJAVai_h9C